Businesses in cold climates can assess natural freezing as a wastewater treatment option. Across six Finnish sites, ice formed with substantially lower impurity levels than the water beneath it, with separation efficiencies of 65–90%. Cleaner ice was harder to break, so harvesting equipment needs to account for both ice purity and thickness. Electrical conductivity, a quick measure of dissolved ions, tracked average ice strength and may help guide harvesting, although strength varied between ice layers.